Q
Can you show me details of multi-level collection device for wax collection (heated tubes from graphite box to collector also ?)
A
Yes, DMF will offer multi-level collection device for wax collection (heated tubes from graphite box to collector.
-
Q
The hot water temperature regulation/ heater is also included in control unit of furnace or separate ?
A
The hot water temperature regulation is set separately, while the heater is included in control unit of furnace.
-
Q
Min and max negative pressure for Ar dewaxing ?
A
Negative Pressure for Ar Dewaxing Max= 35mbar Min=5mbar
-
Q
Max Ar pressure for sintering with Argon atmosphere (without diffusion pump) ? 1000 mbar pressure OK ?
A
∴Max Ar pressure for sintering with Ar (without diffusion pump) =40mbar ∴1000 mbar pressure is availabe but will increase at least 10% equipment cost.
-
Q
If sintering in Ar atmosphere, all the furnace is also under Ar atmosphere at same pressure ?
A
It can be regarded as the same pressure although the pressure near the vacuum access is a bit lower which can be ignored.
-
Q
Floor footprint / Overall dimensions of furnace ?
A
DMF will offer the layput as per requirment in details.
-
Q
Requirements (cooling water/compressed air....) ?
A
Cooling Water: 0.1~0.25MPa, diameter 2", 6~8M3/h
-
Q
Ubwino wa Ar wofunikira?
A
Chiyero cha Argon: 99.999%
-
Q
Kumbali yogula/kayendetsedwe, mungatidziwitse kuti HS Code pazidazi ndi chiyani (mwina zikhala zoposera imodzi)? Tikufuna kuti chidziwitsochi chiwone ntchito zomwe zingagwiritsidwe ntchito poitanitsa makinawo.
A
Khodi ya HS (Digit 10 Khodi Yogwirizana): 8514109000
-
Q
Kodi mungandiuzeko za njira ndi njira zodzitetezera tikamagwiritsa ntchito mpweya wa H2 potenthetsa? Zingakhale zothandiza kutiuza kusiyana ndi nkhani ya mpweya wa N2.
A
Inde, chonde onani bukhu lamanja moyenerera. Zalembedwa mu Chingerezi ndi Chitchaina